| Airborne Particle Counters |
100
LPM Flow Rate
Saves time in Cleanroom Testing
International GMPs require the sampling
of a full cubic meter of air per location
in Grade A environments, for certification
/ validation testing. Traditional 1 CFM
particle counters take over 35 minutes
at each location to sample a full cubic
meter of air. The SOLAIR 3350 / 5350 and
SOLAIR 3350Rx / 5350Rx particle counters
perform this testing in just 10 minutes
(a time savings of 25 minutes per location!).
In comparison to 50 LPM units the SOLAIR
3350 / 5350 and SOLAIR 3350Rx / 5350Rx
particle counters save 10 minutes per
location.
This equates to time and money saved in
terms of testing cleanrooms and getting
facilities up and running faster.
ISO 14644-1 defines the requirements for
the minimum sample volume per location
as a function of the class limit for the
largest considered particle size. For
some cleanrooms this volume can be extremely
high, depending upon the largest considered
particle size. With the SOLAIR 3350’s
minimum detection of 0.3 micron, cleanroom
testing of ISO 2 thru ISO 9 cleanrooms
can be done in considerably less time.
|
|
| Portable Products
> SOLAIR 3350Rx |
| SOLAIR 3350Rx |
| |
| With
fast, reliable sampling of one
cubic meter of air in only ten
minutes, the SOLAIR 3350Rx
portable airborne particle counters
offer sensitivities of 0.3 microns,
at a flow rate of 100 liters per
minute or 3.53 CFM. Housed in
a sleek 316L stainless steel enclosure,
the SOLAIR 3350Rx
is ideal for use in facilities
that require instrument wipe-down.
The built-in 5.7-inch (14.47
cm) color touch screen makes the
SOLAIR 3350Rx
easy to configure and operate.
The instruments can store up to
3,000 records of particle count
data from up to 6 channels. All
data can be quickly and reliably
transferred to a computer, printed
on the built-in thermal printer
or transferred to a USB Flash
Drive.
Multiple interfaces - Ethernet,
RS-485, USB and USB Flash Drive
- make communicating with these
instruments extremely flexible.
The SOLAIR 3350Rx
can be used as portable instruments
or integrated into a facility
monitoring system. |


|
|
|
| Features |
Benefits |
Applications |
- SOLAIR 3350Rx: 0.3-25.0µm
Size Range
- Extreme Life Laser Diode Technology
>20 Years MTTF Laser Lifespan
@ 0.3µm
- 100 Liters per Minute or 3.53
CFM Flow Rate
- Closed-loop Controlled Clean
Pump Technology
- Designed to Enable 21 CFR
Part 11 Compliance (With Additional
LMS Express Software)
- Built-in Thermal Printer
- 316L Stainless Steel Construction
- USB Flash Drive Data Transfer
- Multiple Communication Interfaces
- RS-485, Ethernet, USB and
USB Flash Drive
- 5.7-inch (14.47 cm) Color
Touch Screen
- Designed for ISO 21501-4 Compliance:
Unit-to-Unit Accuracy &
Repeatability Assured
- 3000-record Data Storage Memory
- 200 Alphanumeric Location
Labels
- Open Architecture Connectivity
with OPC Server
- Test Wizard for Cleanroom
Pass/Fail Reports: FS-209E,
ISO-14644-1 or EU GMP Annex
1
|
- Reduced Sample Time:
(1 Cubic Meter in 10 minutes)
- 2 Year Warranty
- Cost Effective Price per Point
- Easy Integration to External
Systems
with OPC Server
- Easy Data Transfer with USB
Flash Drive
|
- Cleanroom Monitoring
- Cleanroom Certification for
EU GMP or ISO 14644
- Facility Monitoring
- Cleanroom Performance Verification
- Trend Analysis
- Routine Cleanroom Testing
- Cleanroom Packaging
- Filter Testing
|
|
|
| |
| Specifications |
Size Range:
|
0.3 - 25.0μm |
Channel
Sizes:
|
0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm
0.3, 0.5, 1.0, 5.0, 10.0, 25.0μm |
Flow Rate:
|
100 LPM or 3.53 CFM |
Counting
Efficiency:
|
3350Rx = 50% @ 0.3μm; 100%
for particles > 0.45μm,
per ISO 21501-4 |
| Light Source: |
Extreme Life Laser Diode Technology
with >20 Year Mean Time To Failure
(MTTF) |
Zero Count
Level:
|
<1 count / 5 minutes
(per JIS) |
| Concentration Limits:
|
200,000 particles / ft3 (7,060,00
particles / m3) @ 5% coincidence
loss. Suitable for all Cleanrooms
ISO Classes 1 thru 9 |
Calibration:
|
Factory Calibrated to ISO 21501-4
including Resolution and Counting
Efficiency tests using NIST-traceable
particles |
Count Modes:
|
Manual, Automatic, Concentration
and Real Time (with LMS Pharma Edition
or LMS Express 7.0 RT) |
Data Storage:
|
3,000 Sample Records (Rotating
Buffer) which includes particle
data, environmental data, locations
and times |
Communication
Modes:
|
RS-485/MODBUS; RS-232;
Ethernet TCP/IP; Universal Serial
Bus; USB Flash Drive |
Supporting
Software:
|
LMS XChange, LMS Express 7.0,
LMS Express RT, LMS Pharma Edition,
ANY OPC Client (with LMS Express
7.0 OPC Server) |
Touch Screen
Display:
|
5.7-inch (14.47 cm) color, 320x240 |
| Printer: |
Built-in Thermal Printer |
| Reports: |
ISO-14644-1, FS-209E & EU
GMP Annex 1 |
| Alarm: |
Internal Adjustable Alarm, Alarms
on Counts and Low Battery |
Enclosure:
|
316L Stainless Steel |
| Sample Output: |
Internally filtered to HEPA standards
(>99.997% @ 0.3μm) |
Vacuum
Source:
|
Internal closed-loop flow-controlled
pump |
| Power: |
100-240 VAC, 50-60 Hz |
| Battery: |
Li-Ion, Removable & Rechargeable:
Typical Battery Operation - *4 hours;
Typical Re-charge Time - 4 hours |
Dimensions:
|
14.77” (d) x 8.0” (w) x 10.41”
(h) [37.52 x 20.32 x 26.44 cm] |
| Weight:
|
With Battery: 25.0 lbs (11.34
kg) Without Battery: 22.0 lbs (9.98
kg) |
| |
* typical battery operation of
10-minute sample, 10-minute hold
time, repeat |
| Environmental Conditions |
| Operating:
|
50°F to 104°F (10°C
to 40°C) / 20% to 95% non-condensing |
| Storage:
|
14°F to 122°F (-10°C
to 50°C) / Up to 98% non-condensing |
| Accessories |
| Included:
|
Operating Manual on
CD; Data Cable; Isokinetic Sample
Probe with Tripod and Tubing; Purge
Filter; Removable/ Rechargeable
Li-Ion Battery; Power Cable and
Spare Fuse; LMS XChange Software;
Printer Paper |
| Optional:
|
Printed Operating Manual;
Cleanroom Cart; Cleanroom Thermal
Printer Paper; Spare Removable/Rechargeable
Li-Ion Battery; External Battery
Charger; USB Flash Drive; LMS Express
RT Software; LMS Pharma Edition
Software; Validation Manual |
|
|
| |
| [ Back to